oil Particle Counter

oil Particle Counter

oil Particle Counter for testing oils with viscosity up to 200 square millimeters per second (mm2 / s) and is one of the laboratory equipment for oil and gas

 

Oil particle counting machine

 

The oil Particle Counter consists of two modules: a sample delivery system (SDS) and a particle counting module (PCM). PCM can be used independently as a portable tool for testing light lubricants and oils with viscosities up to 64 mm / s. This device can record up to 600 measurements and has three internal test methods: ASTM D7647, ISO 60970 and ISO 4406.

With a simple test method, 3 minutes of test time and user-friendly operations, the particle counter requires minimal operator skill or expertise. The progress and test results for the six maximum size bars are displayed as cumulative particles per milliliter and show the cleanliness code ISO 4406, NAS 1638 and AS4059.

For the treatment of lubricating and hydraulic oils, this tool is equipped with perfluorine elastomer seals (FFKM) for resistance to synthetic oils. Operation is done through a round and wide control with a high-visibility screen. Viscosity, darker or more opaque oils can be tested using dilution techniques.

When connected to a PC, the oil Particle Counter can be operated through the provided analysis software, which allows the user to control the tool, create and edit test methods, and test methods. Analyze and save.

Regular monitoring of the number of particles in hydraulic and lubricating oils helps prevent damage caused by particle contamination and reduces mechanical failure time.

oil Particle Counter can be highly abrasive and shorten the life of mechanical components, including bearings and seals. Contamination can be caused by dust, component erosion, or oil breakdown and aging.

Particle contamination monitoring provides data that supports preventative maintenance programs that allow oil changes to be made before irreparable damage to the system occurs. Potentially save money and provide an overview of the overall system situation.

Liquid Oil Particle Counter

L02A oil particle counter conforms to ISO4406 standard, with high pressure pump, which pressure can reach 1 MPa and maximum viscosity up to 1500 cST. it is widely used in aerospace, electric power, petroleum, chemical industry, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields. It is mainly used for the detection of solid particle contamination of hydraulic oil, lubricating oil, transformer oil (insulating oil), turbine oil (turbine oil), gear oil, motor oil, aviation kerosene and water-based hydraulic oil. Besides, it is also used for the detection of insoluble particles of organic liquid and polymer solution.

Liquid Oil Particle Counter

Overview oil particle counter

L02A oil liquid particle counter is in line withISO4406, with high pressure pump, the pressure of which can reach 1 MPa, the maximum viscosity can reach 1500 cST. It is widely used in aerospace, electric power, petroleum, chemical industry, transportation, ports, metallurgy, machinery, automobile manufacturing and other fields. It is mainly used for the detection of solid particle contamination of hydraulic oil, lubricating oil, transformer oil (insulating oil), turbine oil (turbine oil), gear oil, motor oil, aviation kerosene and water-based hydraulic oil. In addition, it is also used for the detection of insoluble particles of organic liquid solution and polymer.

L02A oil liquid particle counter uses laser block method, with long-life and high stability import semiconductor laser light source; 24 detection channels; Imported precision syringe pump sampling control system, high precision sampling, arbitrarily set sampling volume; Large 7-inch true color LCD touchscreen, built-in calibration curves and powerful, easy-to-use database management module; USB interface, data storage is not restricted, you can easily transfer data and save it to your computer.

Characteristics oil liquid particle counter

1. Imported semiconductor laser and specific built-in driver chips can ensure the stability and long service life of the sensor;

2. Adopts imported precision syringe pump sampling system, the sampling is high precision;

3. Positive / negative sample chamber device to perform degassing and high viscosity sample test;

4. 8 test channels, with functions of particle size distribution detection and statistics;

5. Built-in ISO4406, GB / T14039, NAS1638, JBT9737.1, SAE749D, GJB420A, GJB420B, DL / T1096, particle contamination level standards and user-defined parameters for the particle channel; can integrated required standard according to user requirements;

6. Instrument calibration according to GB / T18854-2002 (ISO11171-1999, JJG066-95), ISO4402, latex standard and can achieve automatic size conversion of different standards;

7. Built-in built-in relational database software, able to query the desired result, unlimited data storage, intuitive display and data analysis histogram, for easy data analysis;

8. Large TFT LCD display, touch screen operation and user-friendly interactive interface provide customers with good user experience;

9. External USB interface, directly back up data to computer through U disk, also connect computer through RS232 serial port. Can analyze, verify and print previous internal data in the computer;

10. Can be equipped with high pressure pump, pressure up to 1MPa, maximum viscosity 1500cSt;

11. Can be used with a large volume sampler of up to 2000 ml.

 

Technical specifications 

1. Optical system: laser block, semiconductor laser light source

2. Detection range: 0.8µm (ISO4402) or 3µm (ISO11171) -400µm

3. Detection channels: 8

4 channels, the particle size range of 0.8 µm (ISO4402) or 3 µm (ISO11171) -100 µm set arbitrarily by the user, the interval 0.1 µm4. Sample volume: bottle

5. Maximum sample chamber volume: 0.08MPa

6. Maximum pressure of the sampling booth: 0.7MPa

7. Sample viscosity: 2-600cST

8. Test sample temperature: 0 ~ 8 ° C

9. Sample flow: 5 ~ 100ml / min

10.Test range: 0 ~ 9999999 particles

11. Accuracy: ± 5% of nominal value

12. Repeatability: RSD <2% (particles> 1000 pc / ml, 5 ml

13. Accuracy of sample volume: <± 1%

14.resolution: <10% (gbt18854-2002)

15. Best detectable concentration: 0 ~ 18,000 particles / ml

16.Display operation: 7 inch large screen color LCD touch screen

17.Data output: built-in printer, RS232 interface, USB interface

18. Database software: provides statistics, querying, analysis and data storage functions

19.Rated voltage: AC220V ± 10%, 50Hz, <80w

20. temperature: 10 ~ 40 ° c